Section 2408. Steel Structures.

2408.01 DESCRIPTION.
The provisions of this section shall apply to fabrication and erection of all types of bridge structures in which the main members spanning the various supports are composed of steel and of other structures or parts of structures where the design or intended use of steel is based on physical or chemical properties of the steel. Unless modified elsewhere in the contract documents, all fabrication to which this section applies shall be done in the states, territories, and possessions of the United States and in other locations within the geographic limits of North America and only in steel fabrication shops and plants that are approved as per Materials I.M. 557 prior to the letting. All main member fabrication, except bearing devices, shall be fabricated by plants certified as Category III, Major Steel Bridges, under the provisions of AISC's Quality Certification Program. The steel superstructure will be placed on a substructure constructed as provided in Section 2405. The requirements of Sections 2403, 2404, 2410, 2411, 2412, 2413, and 2508 shall apply to the various types of construction. The various types of structures shall be built in conformance with the contract documents.

2408.02 WORKING DRAWINGS, SHOP DRAWINGS, CHANGES, AND SUBSTITUTIONS.
The Contractor shall submit six copies of detailed shop drawings to the Engineer for review. Welding procedures shall be considered an integral part of shop drawings and shall be reviewed for each contract.

2408.03 QUALITY OF WORK AND FINISH.
Quality of work and finish shall be equal to the best practice in modern bridge shops. Shearing and chipping shall be neatly and accurately done, and all portions of the work exposed to view shall be neatly finished.

2408.04 MATERIAL AND MATERIAL IDENTIFICATION.
The following base materials required in steel structures shall meet requirements of Division 41.

2408.05 FASTENERS.
Where indicated in the contract documents, "rough bolted connections" may be used. In these connections, bolts may be hex-head bolts meeting requirements of ASTM A 307. Ribbed bolts may be used only when specified in the contract documents. Each ASTM A 307 hex-head bolt shall be fitted under the nut with one ANSI B18.21.1 helical spring lock washer, except that expansion joint bolts that are to be removed after the expansion joint is installed or anchor bolts through slotted holes where a cut washer is provided shall not require helical spring lock washers.

When rough bolts or ribbed bolts are to be used, the number of each size and length furnished shall be 5% greater than the number shown in the contract documents. When turned bolts or high strength bolts are to be used, the number of bolts of each size and length and the corresponding number of washers and nuts furnished shall be 2% greater than the number shown in the contract documents.

2408.06 PINS AND ROLLERS.
Pins and rollers shall be turned to the specified dimensions and shall be smooth, straight, and free from flaws.

Pins and rollers more than 9 inches (225 mm) in diameter shall be forged and annealed.

Forgings for pins larger than 9 inches (225 mm) in diameter shall have a 2 inches (50 mm) diameter hole bored longitudinally through the center after the forging has cooled below the critical range and before the forging is annealed. Pins showing a defective interior condition shall be rejected.

2408.07 SHOP STORAGE OF MATERIAL.
Structural material, either plain or fabricated, shall be stored above ground upon platforms, skids, or other supports. It shall be kept free from dirt, grease, and other foreign material.

2408.08 STRAIGHTENING MATERIAL AND PLACING MEMBERS.
All rolled material must be straight when it is laid out for work. If straightening is necessary, it shall be done by means which will not damage the metal. Sharp kinks or bends will be sufficient cause for rejection of the material. Heat correction shall be done only when approved by the Engineer. Unless otherwise shown in the contract documents or ordered by the Engineer, members which deviate from a straight line by an amount within the tolerance specified in ASTM A 6/A 6M shall be placed in the structure so that the stress to be imposed will tend to straighten the member. Heat straightening of ASTM A 709/A 709M Grade 100/100W (Grade 690/690W) steel will not be permitted.

2408.09 BARS AND PLATES.
Unless otherwise noted on the plans, and as excepted below, all main stress carrying members composed of plates and all steel material designated on plans as "bar" or "UM plate" shall have rolled edges or may be thermal cut, provided that with thermal cut plates a smooth surface is secured by the use of a mechanical guide approved by the Engineer in accordance with Article 2408.13. Web splice plates and bearing stiffeners 5/8 inch (16 mm) or less in thickness may be made of sheared plates.

Unless otherwise noted in the contract documents, secondary stress members may be made of sheared plates. If sheared plates are used, their exposed sharp corners shall be dulled by grinding.

Plates shall be cut so the direction of stress in main members is in the direction of rolling, except web splice plates.

Main stress carrying members shall be those members defined in Article 2408.04 as main members.

2408.10 BENT PLATES.
Unwelded, cold bent, load carrying, rolled steel plates shall conform to the following:

2408.11 SHEARED EDGE FINISH.
Sheared edges of plates more than 5/8 inch (16 mm) in thickness and carrying calculated stress shall be planed to a depth of 1/4 inch (6 mm) and ground, if necessary, to secure a finish equivalent to an ANSI 1,000 (25 µm) surface roughness. Re-entrant corners shall be filleted to a minimum radius of 1 inch (25 mm) before cutting.

2408.12 THERMAL CUTTING.
Article 2408.13 shall apply. Thermal cutting of main stress carrying members shall be done only when the steel in the area of the cut is above 40°F (4°C) and in a dry surface condition.

2408.13 WELDING.
Welding procedures and requirements for the following items shall conform to the ANSI/AWS D1.1 Structural Welding Code, except that filler metal and welder qualification requirements shall be according to AWS D1.5 - 95 as modified below.

Welding and fabrication of steel structures shall conform to ANSI/AASHTO/AWS D1.5-95, as modified by this Specification.

Each of the modifications in this Article is referenced by the appropriate paragraph number in ANSI/AASHTO/AWS D1.5-95, to which it is a modification.

SECTION 1. General Provisions

SECTION 3. Workmanship

SECTION 5. Qualifications

Part A. General Requirements

Part B. Welder, Welding Operator, and Tack Welder Qualification

SECTION 6. Inspection

Part A. General Requirements

Part B. Radiographic Testing of Groove Welds in Butt Joints

2408.14 STRESS RELIEF HEAT TREATMENT.
Structural members which are indicated in the contract documents to be stress relieved, shall have finished machining, boring, and straightening done subsequent to heat treatment. Stress relief heat treatment shall be done in accordance with AWS D1.5 Section 4.4.

Members of ASTM A 709/A 709M Grade 100/100W (Grade 690/690W) steel shall not be annealed or normalized and shall be stress relieved only with approval of the Engineer.

A record of each furnace charge shall identify pieces in the charge and show the temperatures and schedule actually used. Instruments such as recording pyrometers shall be provided for determining at any time the temperature of members in the furnace. Records of the treatment operation shall be submitted to the Engineer for approval.

All members, such as bridge shoes, pedestals, rockers, or other parts, which are built up by welding sections of plate together, shall be stress relieved, unless otherwise stated in the contract documents.

2408.15 PLATE GIRDERS.
Plate girders shall be fabricated in accordance with the following requirements:

2408.16 CAMBER OF ROLLED BEAM AND PLATE GIRDER SPANS.
Rolled beams and plate girders constituting the main supporting members of a span shall be cambered in accordance with the following: When specified in the contract documents, rolled beams and plate girders shall be cambered. Unless otherwise specified in the contract documents, this camber shall be a uniform, approximately circular curve for the entire length of the beam or between designated points. Compound or reverse curves may be required on special designs as shown on the plans.

Camber of beam spans may be produced either in the rolling mill or in the fabricating shop by gagging. Camber of beam spans may also be induced or corrected by local heating. In all cases, beams shall conform to the specified shape within tolerance limits. Beams shall be free from kinks, buckles, or other local imperfections. Improper heating or cooling which might affect grain structure, strength, or ductility of the metal shall be cause for rejection.

Rolled beams may be cambered by heating in the following manner: Welding of cover plates shall be completed before commencing final heating operations. The beam shall be supported near its ends in such a manner that the side to be made concave faces upward. An oxyacetylene, butane, natural gas, or other approved gas flame shall be applied to areas so selected that distortion other than the required camber will not occur. Heat shall be applied by playing the flame over the section to be heated until the metal attains a maximum temperature of 1,000°F to 1,200°F (540°C to 650°C). Procedures used for controlling the temperature shall include the use of temperature indicating crayons, liquids, or bimetal thermometers. The Engineer shall be notified before any heating is done.

The heated areas shall be wedge or triangular shaped with an included angle between 20 and 45 degrees. The vertex of the angle shall be located approximately 1 inch (25 mm) above the point on the web midway between flanges. The flame from the torch, or torches, shall be slowly played over the area to be heated, commencing at the vertex of the angle and finishing at the widest part of the heated wedge, which shall extend across the width of the flange on the side to be made concave. The torch, or torches, shall be so manipulated that the total area of the heated zone shall rapidly be brought to the proper temperature at the same time, as nearly as practicable.

The heated sections shall be uniformly spaced at short intervals to produce uniform curvature. Not less than three sections shall be heated, and heating of additional sections may be required in the case of unusually long or heavily cambered beams. The metal shall be air cooled, slowly and away from wind or drafts. In no case shall water be used to cool the metal, nor shall any area be heated more than once.

Plate girders shall be cambered by cutting the web plate to the proper curvature to produce a camber within the allowable tolerance. Cutting of the web plate shall include an allowance to compensate for the effect of the heat of welding operations to be performed on the girder during fabrication.

Camber in plate girders shall not be induced or corrected by local heating unless prior approval is obtained from the Engineer. Heating of ASTM A 709/A 709M Grade 100/100W (Grade 690/690W) steels will not be permitted.

2408.17 BOLT HOLES.
All holes for bolts shall be made by punching or drilling. Holes in all metal thicker than 3/4 inch (19 mm) for carbon steel and 5/8 inch (16 mm) for alloy steel shall not be made by punching, but shall be subdrilled and reamed or shall be drilled full size. Holes in main stress carrying members shall be subpunched and reamed, subdrilled and reamed, or drilled full size. Holes in other than a main stress carrying member in metal not thicker than 3/4 inch (19 mm) for carbon steel and 5/8 inch (16 mm) for alloy steel shall be punched or drilled full size.

When reaming is required all holes shall be subpunched or subdrilled.  Subdrilling will be required if thickness limitations govern.  The subpunching or subdrilling shall be 3/16 inch (5 mm) smaller and, after assembling, reamed 1/16 inch (2 mm) larger or drilled full size to 1/16 (2 mm) larger than the nominal diameter of the bolts.

All steel templates shall have hardened steel bushings in holes accurately dimensioned from the centerline of the connections as inscribed on the template.  The centerline shall be used in accurately locating the template from the milled or scribed ends of the members.

2408.18 REAMING SUBPUNCHED FIELD CONNECTIONS.
When subpunched and reamed holes are required for field connections, main members of the structure shall be fully assembled and firmly bolted together, and their members adjusted to line and fit before holes in connecting joints are reamed. Before the parts are disassembled for shipping and handling, the respective pieces shall be matchmarked with a low stress riser steel stamp so that they can be reassembled in the same position when the structure is erected in the field. Steel stamping on the edges of plates will not be permitted.

In lieu of subpunching and reaming holes, it is permissible, at the option of the fabricator, to drill holes full size while members are assembled by any of the following procedures:

The accuracy of drilled holes shall be as specified in Article 2408.17, Paragraph C.

Reamed parts shall not be interchanged. Connecting joints, such as floor beam and stringer connections not assembled as provided above, shall be reamed to a metal template.

2408.19 SHOP ASSEMBLY.
The various parts of the structure which are to be fastened together in the shop shall be assembled in accordance with the following:

2408.20 DRIFTING OF BOLT HOLES.
The drifting done during assembling shall be only to bring the parts into position and not sufficient to enlarge the holes or distort the metal.

2408.21 FACING BEARING SURFACES.
Ends of columns and pedestals shall be milled to true surfaces and correct bevels. Warped or deformed base and cap plates shall be planed to fit accurately.

Connection angles for base and cap plates shall be attached to columns before ends are faced. Milling shall be done only after the member has been fully assembled.

Bearing surfaces of warped or deformed base and cap plates that are not to be placed in contact with concrete shall be milled after the plates are attached to the column. Surfaces of base plates that are to be placed in contact with concrete shall be free from warps and other deformations.

Sole plates of beams, girders, and trusses shall have full contact with the flanges, and the bearing surface shall be smooth and true and shall be truly perpendicular to the web of the member. Curved sole plates shall make full line bearing with masonry plates, which line, unless otherwise shown in the contract documents, shall be at right angles to the axis of the beam, girder, or truss, and with the web of the member. Bottom surfaces of masonry plates shall be free from warps and projections. All bearing surfaces of castings are to be machined flat.

The tolerance for flatness for all bearing material in contact with all other material, except as otherwise indicated, shall be 1/32 inch in 12 inches and 1/16 inch (1 mm in 400 mm and 2 mm) tolerance overall.

The degree of surface finish required will be indicated in the contract documents. The surface finish of bearing and base plates and other bearing surfaces that are to come into contact with each other or with concrete shall meet the surface roughness requirements as defined in ANSI B46.1, Surface Roughness, Waviness and Lay, Part 1. Unless otherwise indicated on the plans, the following parts shall be finished to the degree indicated below:

Surfaces of bronze bearing plates intended for sliding bearings shall be smooth and free from surface projections.

In machining sliding bearing surfaces, the cut of the tool shall be in the direction of movement. In machining nonsliding bearing surfaces, the cut of the tool shall be either parallel or normal to the direction of movement.

2408.22 ABUTTING JOINTS.

2408.23 END CONNECTION ANGLES.
End connection angles of floor beams and stringers shall be flush with each other and accurately set to position and length of member. In general, end connection angles shall not be machined unless indicated in the contract documents. However, faulty assembling may be cause for requiring them to be milled, in which case their thickness shall not be reduced by more than 1/16 inch (2 mm) and their bolt bearing value shall not be reduced below the design requirements.

2408.24 BORING PIN HOLES.
Pin holes shall be bored true to detailed dimensions, smooth and straight at right angles with the axis of the member and parallel with each other, unless otherwise required. A finishing cut shall always be made, and the finish shall be in accordance with Article 2408.21.

The length outside to outside of holes in tension members and inside to inside of holes in compression members shall not vary from detailed dimensions more than 1/32 inch (1 mm). Boring of holes in built up members shall be done after the bolting or welding is completed.

2408.25 PIN CLEARANCE.
The diameter of the pin hole shall not exceed that of the pin by more than 1/50 inch (0.5 mm) for pins 5 inches (125 mm) or less in diameter, or 1/32 inch (0.8 mm) for larger pins.

2408.26 FINISHED MEMBERS.
The several pieces forming one built up member shall be straight and close fitting. Finished members shall be true to detailed dimensions and free from twists, bends, open joints, or other defects resulting from faulty fabrication or defective work.

2408.27 SHOP ERECTION.
The main members of trusses, arches, continuous beam spans, bents, towers (each face), plate girders, and rigid frames shall be completely assembled for inspection in the shop when complete assembly is feasible. In lieu of complete assembly, at the option of the Contractor, progressive truss or girder assembly will be permissible, as follows:

As the shop sections are progressively assembled and removed, each retained section shall be placed in the new laydown with the same relative orientation to the erection base line as it was found to have in the previous laydown.

As the shop sections are progressively assembled and removed, suitable marks shall be scribed on the sections remaining so that accurate center to center of bearing dimensions and overall length can be achieved.

2408.28 PILOT AND DRIVING NUTS.
On pin connected spans, pilot and driving nuts shall be furnished for each size pin unless otherwise provided in the contract documents.

2408.29 MILL AND SHOP INSPECTION.
The Contractor shall give the Engineer ample notice of the beginning of work at the mill and shop so that inspection may be provided. Mill inspection of rolling will not be required unless requested by the Engineer. If inspection of rolling is not requested, the Engineer shall be furnished with complete test reports of mill inspections, showing chemical and physical tests for each heat of all structural steel sections as specified in Articles 2408.04 and 4152.02.

Material shall not be fabricated before the Engineer has been notified.

2408.30 SHOP PAINTING.
This specification describes surface preparation and shop painting of weathering and non-weathering structural steel and incidental parts. The work includes preparation of all surfaces to be painted, application of paint, protection, drying of paint coatings, and repairing and repainting of coating damaged in the shop and/or after erection. This specification also includes requirements for water washing of weathering structural steel.

2408.31 MARKING AND SHIPPING.
Bolts of one length and diameter and loose nuts or washers of each size shall be packed separately. Items from different manufacturers or from different lots shall also be packaged separately. Pins, small parts, and small packages of bolts, washers, and nuts shall be shipped in boxes, crates, kegs, or barrels, but the gross weight (mass) of any package shall not exceed 300 pounds (135 kg). A list and description of the contained material shall be plainly marked on the outside of the shipping container.

2408.32 FIELD HANDLING AND STORAGE.
Loading, transportation, unloading, and piling of structural members shall be conducted so that the metal will be kept clean and free from damage by rough handling. Shipping supports, lifting devices, and deck form support points shall be padded to minimize paint damage.

All material shall be stored in a manner to prevent deterioration by rust or loss of minor parts. Material shall not be piled to rest upon the ground or in water, but must be placed on suitable skids or platforms. Girders and beams shall be placed upright and shored. Skids beneath long members, such as columns or chords, shall be close enough to prevent damaging the members by deflection.

2408.33 FALSEWORK.
Detailed plans for falsework or centering shall be supplied to the Engineer. In no case shall the Contractor be relieved of responsibility for results obtained by use of these plans or safety of workers on the project. Adequacy of falsework shall be subject to checking and review by the Engineer before erection of the structure which the falsework is to carry. Falsework for supporting steel during erection shall be designed to carry, without appreciable settlement or deformation, the full load coming upon it. It shall consist of either full length pile bents or framed bents supported by piles or spread footings. Bearing values of piles shall be determined as provided in Article 2501.14 and shall be at least equal to the loads imposed upon them during construction. The number and size of spread footings or mudsills used shall be determined by the load to be supported and the bearing value of the soil on which they rest, due consideration being given to the softening of soils during high water, thawing of frozen ground, etc. Mudsills shall not be used on soils or in situations where scour is likely to occur.

The safe bearing value of sand, gravel, firm clay, and other similar confined materials in beds thicker than the falsework footing width shall be considered 1,500 pounds per square foot (70 kPa).

If necessary to extend falsework above the elevation to which piles are driven, at least the majority of all piles in any bent shall be cut off at the same elevation and capped, and a framed bent shall be constructed to the required height. Each falsework bent shall be capped transversely at the proper elevation with material of adequate size securely fastened to each pile or post in the bent. All bents shall be securely braced longitudinally and transversely with diagonal bracing.

2408.34 PREPARATION OF BEARING AREA.
Column bases, truss and girder pedestals, and shoes shall have a full uniform bearing upon the concrete of the substructure. Bridge seats of piers or abutments which are improperly finished, deformed, or irregular within the bearing area of masonry plates shall be corrected before the plates are placed. Pedestals and shoes for truss and girder spans and columns for steel viaducts shall be bedded on the bearing area so as to have full and even bearing. Unless otherwise required, the bedding shall be a single layer of 1/8 inch (3 mm) sheet lead meeting requirements in Article 4195.01.

2408.35 HANDLING MEMBERS.
Component parts of a structure shall be handled by methods and appliances not likely to produce damage to the member by twisting, bending, or otherwise deforming the metal. Any member that is slightly bent or twisted shall not be put into its place until its defects are corrected. Members that have been seriously damaged in handling may be rejected.

2408.36 STRAIGHTENING BENT MATERIAL.
Straightening of plates, angles, other shapes, and built up members, when permitted by the Engineer, shall be done by methods that will not produce fracture or other injury. Distorted members shall be straightened by mechanical means, or if approved by the Engineer, by the carefully planned and supervised application of a limited amount of localized heat, except that heat straightening of ASTM A 709/A 709M Grade 100/100W (Grade 690/690W) steel members shall be done only under rigidly controlled procedures, each application subject to approval of the Engineer. In no case shall the maximum temperature of ASTM A 709/A 709M Grade 100/100W (Grade 690/690W) steel exceed 1,125°F (610°C), nor shall the temperature exceed 950°F (510°C) at the weld metal or within 6 inches (150 mm) of weld metal. Heat shall not be applied directly on weld metal. In all other steels, the temperature of the heated area shall not exceed 1,200°F (610°C) (a dull red) as controlled by use of temperature indicating crayons, liquids, or bimetal thermometers.

Parts to be heat straightened shall be substantially free of stress and from external forces, except stresses resulting from mechanical means used in conjunction with the application of heat.

Following straightening of a bend or buckle, the metal surface shall be carefully inspected for evidence of fracture. Members showing fracture shall be repaired or replaced.

2408.37 ASSEMBLING STEEL.
Parts shall be accurately assembled as shown in the contract documents and a match marking system shall be followed. Material shall be carefully handled so that parts will not be bent, broken, or otherwise damaged. Hammering which will damage or distort the members shall not be done. Bearing surfaces and surfaces to be in permanent contact shall be cleaned before the members are assembled.

Important connections in trusses, girders, floor systems, etc., shall have at least 25% of the holes on each side of the connection filled with drift pins, and another 25% of the holes on each side of the connection filled with temporary fitting up bolts drawn up snugly before the temporary support is removed. If the ultimate connection is to be made with high strength bolts, these bolts may be used as fitting up bolts. At milled connections of compression chords of truss spans, except the hip connection, the number of drift pins may be reduced to not less than 10% of the number of holes.

2408.38 ALIGNMENT.
Before placing permanent bolts in field connections, the structure shall be adjusted to correct grade and alignment. For truss spans, the elevation of each panel point (ends of floor beams) shall be blocked up on the falsework to the correct camber as shown in the contract documents and shop drawings. This blocking shall remain in place until all tension chord splices are fully bolted and all other truss connections are pinned and bolted.

Splice joints of continuous beams and girders shall be supported by adequate falsework or other approved means as directed by the Engineer, and adjusted as closely as possible to the required position before bolting is started.

2408.39 BOLTING.
Main connections shall be made with high strength bolts, nuts, and washers meeting requirements of Article 4153.06. All other fasteners will be considered non-high strength fasteners and may be used only where shown on the plans.

2408.40 SWINGING THE SPAN.
After permanent bolting of truss spans has been inspected and accepted, the centering shall be removed and the span swung free on its permanent supports. All main connections shall be fully bolted before the span is swung, except that milled compression chord connections shall be permanently bolted after the span is swung.

2408.41 ADJUSTMENT OF PIN NUTS.
All nuts on pins shall be adjusted to the amount specified in the contract documents. The pins shall be located in the holes so that the members shall take full and even bearing upon them.

2408.42 SETTING ANCHOR BOLTS.
For setting anchor bolts for bridge bearings, see Article 2405.09.

Anchor bolts, other than those for bridge bearings, shall be set in concrete with a polymer grout, as described in Article 2405.09, or with a mechanical grip system. When the mechanical grip system is used, the diameter of the hole shall be suitable for the device used, the anchor shall be held firmly in place by an expanding metal device approved by the Engineer, and the annular space shall be filled with cement grout or other material approved by the Engineer.

2408.43 SETTING ROCKER BEARINGS.
Rocker bearings at expansion ends of spans shall be adjusted to provide for movement due to temperature, for elongation of bottom chord, and for probable substructure movement. The mean temperature assumed shall be 50°F (10°C), in determining temperature movements.

2408.44 FIELD PAINTING.
Field painting of steel structures or parts of structures shall be as required in the contract documents.

2408.45 METHOD OF MEASUREMENT.
The quantity of various items of structural concrete, steel reinforcement, structural steel, and incidental metal parts, involved in construction of steel structures will be computed by the Engineer as follows:

2408.46 BASIS OF PAYMENT.
The Contractor will be paid for various items of Structural Concrete, Steel Reinforcement, Structural Steel, and Incidental Metal Parts as follows: