Procedure to Determine Datum Temperate

Setting for Humboldt Type Maturity Meters

 

Key Displays

 

Press ENTER PRESENT VALUES

CH 1 Temp: XX

 

 

Press REC RECORDING

1.    START

 

 

Press REC SETUP

1.    DATUM TEMP

 

 

Press ENTER SETUP

DATUM TEMP: -10 C

 

 

If datum temperature is not set to -10 C, press the up (↑) or down (↓) arrows to set the maturity meter to 10 C. Then press ENTER to save the settings.

 

 

Setting datum temperature varies for other maturity meters. Consult the manual from the manufacturer.